Basic configuration
- Main parts: the host, 1.8 m connection cable, two mounting nuts, operating manuals
- Option: 3 m long cable, other lengths upon request customized
- Optional accessories: secondary display meter, air purge, fixed mount bracket, adjustable mounting bracket
Basic parameters
- Level of environment: IP65 (NEMA – 4)
- Ambient temperature :0-60
- Storage temperature: -20-80
- Relative humidity :10-95%, non-condensing
- Electrical parameters
- Analog Output :4-20mA
- Maximum load: 500Ω (pure resistive load)
- Cable length: 1.8m (Standard) 3m 8m15m and special specifications (custom)
- Power supply: 24 VDC
- Measurement parameters
- Measurement range :0-500
- Accuracy: ± 1%
- Repeatability: ± 0.5%
- spectral response:8-14μm
- Response time: 500 ms (95)
- Distance coefficient: 15:1
- The temperature resolution: 0.1
- Emission rate: 0.95 (adjustable)