| MODEL | T-120A | T-120B | T-120C | T-120D | ||||||||
| DC VOLTAGE | 5V | 12V | -5V | 5V | 12V | -12V | 5V | 15V | -15V | 5V | 12V | 24V |
| RATED CURRENT | 2~11A | 0.5~5A | 0.2~1A | 2~11A |
0.5~ 4.5A |
0.2~1A | 2~10A |
0.5~ 3.5A |
0.1-1A | 2~12A | 0.2~ 0.5A |
0.2~ 2A |
| RIPPLE&NOISE |
80m Vp-p |
150m Vp-p |
150m Vp-p |
80m Vp-p |
150m Vp-p |
150m Vp-p |
80m Vp-p |
150m Vp-p |
150m Vp-p |
80m Vp-p |
120m Vp-p |
180m Vp-p |
| EFFICIENCY | 77% | 77% | 76% | 80% | ||||||||
| ADJUSTABLE RANGE FOR DC VOLTAGE |
±10% | ±5% | ±5% | ±10% | ±5% | ±5% | ±10% | ±5% | ±5% | ±10% | ±5% | ±5% |
| LINE REGULATION | ±0.5% | ±1% | ±1% | ±0.5% | ±1% | ±1% | ±0.5% | ±1% | ±1% | ±0.5% | ±1% | ±1% |
| LOAD REGULATION | ±1% | ±5% | ±5% | ±1% | ±5% | ±5% | ±1% | ±6% | ±6% | ±0.5% | ±5% | ±5% |
|
SETUP,RISE,HOLD UP TIME |
200ms,50ms,16ms/230VAC at full load | |||||||||||
|
VOLTAGE RANGE |
90-132VAC/180-264VAC by switch 254~370VDC | |||||||||||
|
FREQUENCY RANGE |
47-63HZ | |||||||||||
| IMPACT CURRENT | Cold start current 30A/115VAC 60A/230VAC | |||||||||||
|
OVERLOAD PROTECTION |
105-150% cut offtheoutput, automatic recovery | |||||||||||
| OVER VOLTAGE PROTECTION | CH1:115-135% shut down O/P voltage ,re-power on to recover. | |||||||||||
| WORKING TEMP | -10~ +50°C | |||||||||||
|
WITHSTAND VOLTAGE |
I/P-O/P:1.5KV I/P-FG:1.5KV O/P-FG:0.5KV 1minute | |||||||||||
|
ISOLATION RESISTANCE |
I/P-O/P,I/P-FG,O/P-FG:500VDC/100M Ohms | |||||||||||
| DIMENSION | 199*110*50mm | |||||||||||
| WEIGHT | 0.9kg | |||||||||||
| PACKING | 42*31.5*26cm/20pcs/18kg | |||||||||||