Model Specification |
SP-100-5
|
SP-100-7.5
|
SP-100-12
|
SP-100-15
|
SP-100-24
|
SP-100-48
|
DC output voltage |
5V
|
7.5V
|
12V
|
15V
|
24V
|
48V
|
Output voltage error(Note:2) | ±2% |
±1%
|
±1%
|
±1%
|
±1%
|
±1%
|
Rated output current | 20A |
13.5A
|
8.5
|
6.7A
|
4.5A
|
2.2A
|
Output current rage | 0-20A |
0-13.5A
|
0-8.5
|
0-6.7A
|
0-4.5A
|
0-2.2A
|
Wave and noise(Note:3) |
100mVp-p
|
125mVp-p
|
125mVp-p
|
125mVp-p
|
150mVp-p
|
150mVp-p
|
Inlet stability(Note:4) |
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
Load stablity (Note:5) |
±1%
|
±0.5%
|
±0.5% |
±0.5%
|
±0.5%
|
±0.5% |
DC output power |
100W
|
101W
|
102W
|
100.5W
|
108W
|
105.6W
|
Efficiency |
76%
|
78%
|
80%
|
81%
|
83%
|
84%
|
Adjustable range for DC voltage |
+10%
|
+10%
|
+10%
|
+10%
|
+10%
|
+10%
|
AC input voltage range | 85-132VAC /176~264VAC selected by swich 47~63Hz;248~370VDC | |||||
Input current | 2A/115V 1A/230A | |||||
AC INnrush current | Cold-start current30A/115V 60A/230V | |||||
Leakage current | <1mA/240VAC | |||||
Overload proctection | 105%-150%Type:Foldback:current limiting reset:auto recovery | |||||
Over-voltage protection | 115%-135 | |||||
High-temperature protection | ………… | |||||
Temperature coefficient | ±0.03%/℃(0-50℃) | |||||
Setup rise hold up time | 1s,30ms,15ms | |||||
Vibration | 10-500Hz,2G 10min,/1cycle,Period for60min,Each axes | |||||
Withstand voltage | Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC | |||||
Isolation resistance | Input and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ | |||||
Working temperature and humidity | -10℃~+60℃(Refer to output derating curve),20%~90%RH | |||||
Store temperature and humidity | -20℃~+85℃。10%~95%RH | |||||
Overall dimension | 199×98×38mm | |||||
Weight | 0.65Kgs | |||||
Safety standards | UL1012 TUV EN6050(IEC950,UL1950)Approved | |||||
EMC standards | CISPR22(EN55022),IEC801-2,3,4,IEC555-2 Verification | |||||
Note: 1.The testing condition for the paramenter above is :230VAC input,rated load,25℃70% RH.Humidity. 2.Error.include the setting error,line stability and load stability.(Note:5). 3.Wave test:adopting “A12″double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. 4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. 5.Load stability test:the load is from 0% to 100%. 6.C2、3、6must be knocked down. |