| Model | SCN-1200-12 | SCN-1200-24 | SCN-1200-36 | SCN-1200-48 |
| Specification | ||||
| DC output voltage | 12V | 24V | 36V | 48V |
| Rated output current | 100A | 50A | 33A | 24A |
| Output current rage | 0-100A | 0-50A | 0-33A | 0-24A |
| Wave and noise(Note :3) | 120mVp-p | 200mVp-p | 200mVp-p | 240mVp-p |
| Inlet stability(Note :4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load stablity (Note :5) | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Efficiency | 80% | 85% | 86% | 87% |
| Adjustable range for DC voltage | ±10% | ±10% | ±10% | ±10% |
| AC input voltage range | 90-132VAC/180-264VAC | |||
| Impact current | Cold start current 45A/230VAC | |||
| Overload proctection | 105%-135%cut off the output,automatic recovery | |||
| Over voltage protection | 115%-140%shut down O/P voltage,re-power on to recover | |||
| Setup rise hold up time | 2000ms,50ms,20ms/230VAC | |||
| Withstand voltage | Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC | |||
| Isolation resistance | Input and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ | |||
| Working temperature and humidity | -10ºC~+50ºC(Refer to output derating curve),20%~90%RH | |||
| Store temperature and humidity | -20ºC~+85ºC.10%~95%RH | |||
| Overall dimension | 291×132×136mm | |||
| Weight | 5.3Kgs | |||
| Packing | 38*37.5*21cm/2pcs/11kg | |||