| Model Specification | S-40-5 | S-40-12 | S-40-15 | S-40-24 |
| DC output voltage | 5V | 12V | 15V | 24V |
| Output voltage error (Note2) | ±2% | ±1% | ±1% | ±1% |
| Rated output current | 8A | 3.4A | 2.8A | 1.7A |
| Output current rage | 0-8A | 0-3.4A | 0-2.8A | 0-1.7A |
| Wave and noise(Note3) | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
| Inlet stability(Note4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load stability(Note5) | ±1% | ±0.5% | ±0.5% | ±0.5% |
| Efficiency | 71% | 78% | 78% | 82% |
| Adjustable range for DC voltage | ±10,-5% | ±10% | ±10% | ±10% |
| AC input voltage range | 90~132VAC/180~264VAC selected by switch | |||
| Input current | 1.3A/115V 0.65A/230V | |||
| AC impulse current | Cold-Start Current 18A/115V 36A/230V | |||
| Leakage current | <0.5mA /240VAC | |||
| Overload protection | 105%~150% Cut Off the Output, Automatic Recovery | |||
| Over-voltage protection | ^^ | |||
| High-temperature protection | ^^ | |||
| Temperature coefficient | ±0.03%°C(0~50°C) | |||
| Setup rise hold up time | 200ms,100ms,20ms/230VAC | |||
| Vibration | 10~500Hz,2G 10min./1cycle,Period for 60min,Each axes | |||
| Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||
| Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/ 25°c/70%RH | |||
| Working temperature and humidity | -10°C~+60°C,20%~90%RH | |||
| Store temperature and humidity | -20°C~+85°C,10%~95RH | |||
| Weight | 0.5kg | |||
| Packing | 34*32*24cm/30pcs/15Kg | |||