Model | S-100-3 | S-100-5 | S-100-7.5 | S-100-12 | S-100-15 | S-100-24 | S-100-27 | S-100-48 |
Specification | ||||||||
DC output voltage | 3V | 5V | 7.5V | 12V | 15V | 24V | 27V | 48V |
Output voltage range (Note:2) | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
Rated output current | 20A | 20A | 13.6A | 8.5A | 6.7A | 4.5A | 3.7A | 2A |
Output current range | 0-20A | 0-20A | 0-13.6A | 0-8.5A | 0-6.7A | 0-4.5A | 0-3.7A | 0-2A |
Wave and noise(note:3) | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Inlet stability(note:4) | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
Load stability(note:5) | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
DC output power | 60W | 100W | 102W | 102W | 100.5W | 108W | 99.9W | 96W |
Efficiency(Typ.) | 70% | 78% | 80% | 81% | 81% | 84% | 84% | 84% |
Adjustable range for DC voltage | 2.85-3V | 4.75-5.5V | 6.75-8.25 | 10.8-13.2V | 13.5-16.5V | 21.6-26.4V | 26-32V | 43.2-52.8V |
AC input voltage range | 85~132VAC/180~264VAC Selected by switch 47~63Hz:255~370VDC | |||||||
Input current | 2.4A/115V 1.2A/230V | |||||||
AC Inrush current | Cold-start current 30A/115V 60A/230V | |||||||
Leakage current | ﹤1mA/240VAC | |||||||
Overload | Type:pulsing hiccup shutdown Reset:auto recovery | |||||||
Over-voltage protection | 105%-150% | |||||||
High-voltage protection | …… | |||||||
Temp coefficient | ±0.03%/℃(0-50℃) | |||||||
Setup, rise, hold up time | 200ms,100ms,30ms | |||||||
Vibration | 10~500Hz,2G 10min,/1cycle,Period for 60min,Each axes | |||||||
Withstand voltage | Input and output intemal: 1.5KvAC,Input and enclosure: 1.5KvAC Output and enclosure: 0.5KvAC | |||||||
Isolation resistance | Input and output intemal, Input and enclosure, Output and enclosure: 500VDC/100MΩ | |||||||
Working temp., humidity | -10℃~+60℃(Refer to output derating curve),20%~90%RH | |||||||
Storage temp., humidity | -20℃~+85℃.10%~95%RH | |||||||
Dimension | 199×98×38mm(L*W*H) | |||||||
Weight | 0.65Kgs | |||||||
Safety standards | Meet UL 1012 requirement(Not apply for the mark) | |||||||
EMC standards | Meet FCC PART 15J Conduction class B | |||||||
Note:1.The testing condition for the paramenter above is: 230 VAC input, rated load, 25 ℃ 70% Rh, temperature. | ||||||||
2.Error.include the setting error.line stability and load stability.(Note:5) | ||||||||
3.Wave test:adopting “A12”double wire for 20MHz,and 0.1UF&0.47UF capacitor short-circuit for interrupting | ||||||||
4.Intel voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. | ||||||||
5.Load stability test:The load is from 0% to 100%. |
S-100 Single output switching power supply
S-100 Single output switching power supply Low price and high reliability 105℃ output capacitor AC input power suitable for the world High efficiency and low operation temperature Soft-start current can reduce the AC input impact effecticly With short -circuit and overload protection Compact size, light weight 100% full-load buming test Installed with EMI filter,minimum wave
หมวดหมู่: S series Switching power supply
ป้ายกำกับ: Switching Power Supply. เพาเวอร์ซัพพลาย, ตัวแปลงไฟฟ้า
รายละเอียดเพิ่มเติม
ข้อมูลเพิ่มเติม
BRANDS |
---|