| INPUT | ||||||||||||
| Voltage Range | 85~264 VAC47-63Hz;120~370VDC | |||||||||||
| AC Current | 2A/115 V0.8A/ 230 V | |||||||||||
| Efficiency | 70%(SKQ-60B); 72%(SKQ-60C); 75%(SKQ-60D) | |||||||||||
| Inrush Current | Cold start 18A/115V36A/230V | |||||||||||
| Leakage Current | <1 mA/240VAC | |||||||||||
| PROTECTION | ||||||||||||
| Over Load | 105%~150% /115VAC | |||||||||||
| Protection type: Shut down o/p voltage, recovers automatically after fault condition is removed | ||||||||||||
| Over Voltage | 5V:115%~135% | |||||||||||
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||||||
| ENVIRONMENT | ||||||||||||
| Working Temp., Humidity | -10℃~+60℃;20%~90 %RH | |||||||||||
| Storage Temp., Humidity | -20℃~+85℃;10%~95 %RH | |||||||||||
| Vibration | 10~500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes | |||||||||||
| SAFETY | ||||||||||||
| Withstand Voltage | I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC | |||||||||||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | |||||||||||
| STANDARD | ||||||||||||
| Safety Standard | Design refer to UL60950 | |||||||||||
| EMC Standard | Design refer to EN55022,EN61000-3-2,-3, EN61000-4-2,3,4,5,6,8,11; ENV50204 | |||||||||||
| Weight | 0.56Kg | |||||||||||
| Packing | 24pcs/14.4Kg/0.75CUFT | |||||||||||
| NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | |||||||||||
| 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ &47μ parallel capacitor. | ||||||||||||
| 3.Tolerance: includes set up tolerance, line regulation and load regulation. | ||||||||||||
| 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. | ||||||||||||
| OUTPUT | ||||||||||||
| Model |
Q-60B | Q-60C | Q-60D | |||||||||
| CH1 | CH2 | CH3 | CH4 | CH1 | CH2 | CH3 | CH4 | CH1 | CH2 | CH3 | CH4 | |
| DC Voltage | 5V | 12V | -5V | -12V | 5V | 15V | -5V | -15V | 5V | 12V | 24V | -12V |
| Voltage Tolerance | ±2% | ±6% | ±5% | ±5% | ±2% | 8% | ±5% | ±5% | ±2% | ±6% | 8% | ±5% |
| -4% | -4% | |||||||||||
| Rated Current | 5.5A | 2A | 0.5A | 0.5A | 5.5A | 1.5A | 0.5A | 0.5A | 4A | 1A | 1A | 0.5A |
| Current Range | 0.5-8A | 0.1-3A | 0-1A | 0-1A | 0.5-8A | 0.1-3A | 0-1A | 0-1A | 0.5-8A | 0.1-3A | 0.1-1.5A | 0-1A |
| Rated Power | 60W | 60W | 60W | 60W | 60W | 60W | 60W | 60W | 60W | 62W | 62W | 62W |
| Ripple & Noise | 100 mVp-p | 120 mVp-p | 100 mVp-p | 120 mVp-p | 100 mVp-p | 120 mVp-p | 100 mVp-p | 120 mVp-p | 100 mVp-p | 120 mVp-p | 150 mVp-p | 120 mVp-p |
| DC Adjustment Range | CH1:-5%,+10% | |||||||||||
| Setup,Rise,Hold Time | 1600ms,20ms,12ms/115VAC800ms,20ms, 60ms/230VAC at full load | |||||||||||
Q-60 Quad output switching power supply
Q-60 Quad output switching power supply Low price and high reliability 105℃ output capacitor AC input power suitable for the world Hight efficiency and low operation temperature Soft-start current can reduce the AC input impact effecticly With Short-circuit and owwerload protection Compact size,light weight 100% full-load burning test Installed with EMI filter,minimum wave