Model | HLG-200-12 | HLG-200-20 | HLG-200-24 | HLG-200-36 | HLG-200-48 | |
output | DC voltage | 12V | 20V | 24V | 36V | 48V |
Constant current region | 6~12V | 10~20V | 12~24V | 18~36V | 24~48V | |
Rated current | 14A | 10A | 8.4A | 5.6A | 4.2A | |
Rated power | 168W | 200W | 201.6W | 201.6W | 201.6W | |
Ripple&noise | 150mvp-p | 150mvp-p | 150mvp-p | 200mvp-p | 200mvp-p | |
Voltage ADJ range | 10.8~13.5V | 17~22V | 22~27V | 33~40V | 43~53V | |
Current ADJ range | Can be adjusted by internal potentiometer or through output cable | |||||
7~14A | 5~10A | 4.2~8.4A | 2.8~5.6A | 2.1~4.2A | ||
input | Voltage range | 90~264VAC,47~63HZ ,127~370VDC | ||||
AC current | 2.0A/115VAC,1.1A/230VAC | |||||
Power factor | PF>0.95/230VAC,PF>0.98/115VAC Start overload protection | |||||
efficiency | 92% | 92% | 93% | 93% | 94% | |
Inrush current | Cold start current 35A/115VAC,75A/230VAC | |||||
Leakage current | < 0.75mA/240VAC | |||||
protection | Over current | 95%~108% | ||||
protection type :Constant current limiting ,auto-recovery after fault condition is removed | ||||||
Short circuit | Hiccup mode,recovers automatically after fault condition is remove | |||||
Over voltage | 14~17V | 23~27V | 28~34V | 41~46V | 54~60V | |
protection type:Shut down o/p voltage re-power on to recover | ||||||
Over temperature | 100℃±10℃(RTH2) | |||||
protection type:Shut down o/p voltage re-power on to recover | ||||||
environment | Working temp,humidity | -20℃~+60℃,20%~90%RH | ||||
Storagetemp,humidity | -40℃~+85℃,10%~95%RH non-condensing | |||||
Withstand vibration | 10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes | |||||
safety | Withstand voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
Isolated resistance | I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC | |||||
Fitstandard | Safety standard | Fit UL1310 CLASS2,TUV EN61347-1,EN61347-2-13, IP65approved | ||||
EMC standard | Fit EN55015,EN61000-3-2 ClassC(>60%load):EN61000-3-3 | |||||
others | Dimension | 247*69*39mm (L*W*H) | ||||
Weight/packing | 1.3kg/20pcs/27kg/0.033m³/1.15CUFT | |||||
note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | |||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. |
HLG-200W Full function adjustable waterproof power supply
HLG-200W series Full function adjustable waterproof power supply
·Universal AC input
·BUilt-in power factor correction
·Protections:short circuit/over load/over voltage/over temp
·Cooling by free air convection
·OCP point adjustable through output cable or internal potentiometer
·IP67/65 design for indoor or outdoor installations
·Suitble for LED lighting and moving sign applications ·3Year warranty
·BUilt-in power factor correction
·Protections:short circuit/over load/over voltage/over temp
·Cooling by free air convection
·OCP point adjustable through output cable or internal potentiometer
·IP67/65 design for indoor or outdoor installations
·Suitble for LED lighting and moving sign applications ·3Year warranty
หมวดหมู่: Waterproof led driver
ป้ายกำกับ: Switching Power Supply. เพาเวอร์ซัพพลาย, ตัวแปลงไฟฟ้า
รายละเอียดเพิ่มเติม
ข้อมูลเพิ่มเติม
BRANDS |
---|