- 170~264VAC AC input
- Small volume,low weight,high efficiency
- Protections:short circuit/over load/over voltage
- Built-in cooling DC fan
- Fully encapsulated with IP44 level
- 100% full load burn-in test
Model | FS-200-12 | FS-200-15 | FS-200-24 | FS-200-36 | FS-200-48 | |
output | DC voltage | 12V | 15V | 24V | 36V | 48V |
Voltage tolerance | ±1% | ±1% | ±1% | ±1% | ±1% | |
Rated current | 16.6A | 13A | 8.3A | 5.5 | 4.2 | |
Current range | 0~16.6A | 0~13A | 0~8.3A | 0~5.5A | 0~4.2A | |
Rated power | 199.2W | 195W | 199.2W | 198W | 201.6W | |
Ripple&noise | 150mvp-p | 150mvp-p | 150mvp-p | 200mvp-p | 200mvp-p | |
DCvoltage ADJ.range | ±10% | ±10% | ±10% | ±10% | ±10% | |
input | Voltage range | 170~264VAC,255~373VDC | ||||
frequency | 47~63HZ | |||||
AC current | 2.5A/230VAC | |||||
efficiency | 82% | 82% | 84% | 85% | 86% | |
Inrush current | Cold start current 45A/230VAC | |||||
Leakage current | < 3.5mA/240VAC | |||||
protection | overload | Rated output power105%~135% start over load protection | ||||
protection type:hiccup mode,auto-recovery after fault condition is removed | ||||||
over voltage | 15.6~17.8V | 18.6~20.8V | 30.6~33.2V | 42.6~44.2V | 54.8~56.6V | |
protection type:hiccup mode,auto-recovery after fault condition is removed | ||||||
environment | Working temp,humidity | -10℃~+60℃,20%~90%RH | ||||
Storagetemp,humidity | -20℃~+85℃,10%~95%RH non-condensing | |||||
Withstand vibration | 10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes | |||||
safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
Isolated resistance | I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC | |||||
Fitstandard | Safety standard | Fit UL1012 IP44 | ||||
EMC standard | EN55022,CLASSA | |||||
others | Dimension | 206*125*50mm (L*W*H) | ||||
Weight/packing | 0.9kg/20pcs/19kg/0.039m³/1.36CUFT | |||||
note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | |||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. |