| MODEL | D-50A | D-50B | D-50C | D-50F | ||||
| DC VOLTAGE | 5V | 12V | 5V | 24V | 12V | -12V | 12V | 24V |
| RATED CURRENT | 0~6A | 0~2A | 0~6A | 0~1A | 1~2A | 0.3~2A | 1~2A | 0.2~1A |
| RIPPLE&NOISE | 50mVp-p | 80mVp-p | 50mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 120mVp-p |
| EFFICIENCY | 73% | 73% | 73% | 73% | ||||
| ADJUSTABLE RANGE FOR DC VOLTAGE | ±10% | ±5% | ±10% | ±5% | ±10% | ±10% | ±10% | ±10% |
| LINE REGULATION | ±0.5% | ±1% | ±0.5% | ±1% | ±1% | ±1% | ±1% | ±1% |
| LOAD REGULATION | ±0.5% | ±4% | ±0.5% | ±1% | ±0.5% | ±5% | ±0.5% | ±8% |
| SETUP,RISE,HOLD UP TIME | 200ms,100ms,30ms at full load | |||||||
| VOLTAGE RANGE | 90-132VAC/180-264VAC by switch 254-370VDC | |||||||
| FREQUENCY RANGE | 47-63HZ | |||||||
| IMPACT CURRENT | Cold start current 18A/115VAC 36A/230VAC | |||||||
| OVERLOAD PROTECTION | 105-150% cut off the output, automatic recovery | |||||||
| OVER VOLTAGE PROTECTION | CH1:115-135% shut down O/P voltage ,re-power on to recover | |||||||
| WORKING TEMP | -10~ +50°C | |||||||
|
WITHSTAND VOLTAGE |
I/P-O/P:1.5KV I/P-FG:1.5KV O/P-FG:0.5KV 1minute | |||||||
|
ISOLATION RESISTANCE |
I/P-O/P,I/P-FG,O/P-FG:500VDC/100M Ohms | |||||||
| DIMENSION | 159*98*38mm | |||||||
| WEIGHT | 0.55kg | |||||||
| PACKING | 34*32*24cm/30pcs/15kg | |||||||