| MODEL | D-60A | D-60B | D-60C | D-60F | ||||
| DC VOLTAGE | 5V | 12V | 5V | 24V | 12V | -12V | 12V | 24V |
| RATED CURRENT | 0~4A | 0~3A | 0~3A | 0~1.8A | 1~2.5A | 0.3~2.5A | 1~2A | 0.2~1.5A |
| RIPPLE&NOISE | 70mVp-p | 150mVp-p | 75mVp-p | 150mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 120mVp-p |
| EFFICIENCY | 73% | 73% | 73% | 73% | ||||
| ADJUSTABLE RANGE FOR DC VOLTAGE | ±10% | ±5% | ±10% | ±5% | ±10% | ±5% | ±10% | ±5% |
| LINE REGULATION | ±0.5% | ±1% | ±0.5% | ±0.5% | ±1% | ±1% | ±1% | ±1% |
| LOAD REGULATION | ±0.5% | ±4% | ±0.5% | ±4% | ±5% | ±5% | ±0.5% | ±8% |
| SETUP,RISE,HOLD UP TIME | 300ms,50ms,80ms at full load | |||||||
| VOLTAGE RANGE | 85-264VAC/120-370VDC | |||||||
| FREQUENCY RANGE | 47-63HZ | |||||||
| IMPACT CURRENT | Cold start current 30A/115VAC 60A/230VAC | |||||||
| OVERLOAD PROTECTION | 105-150% cut offtheoutput, automatic recovery | |||||||
| OVER VOLTAGE PROTECTION | CH1:115-135% shut down O/P voltage ,re-power on to recover. | |||||||
| WORKING TEMP | -10~ +50°C | |||||||
|
WITHSTAND VOLTAGE |
I/P-O/P:1.5KV I/P-FG:1.5KV O/P-FG:0.5KV 1minute | |||||||
|
ISOLATION RESISTANCE |
I/P-O/P,I/P-FG,O/P-FG:500VDC/100M Ohms | |||||||
| DIMENSION | 159*98*38mm | |||||||
| WEIGHT | 0.55kg | |||||||
| PACKING | 34*32*24cm/30pcs/15kg | |||||||