| MODEL | T-50A | T-50B | T-50C | T-50D | ||||||||
| DC VOLTAGE | 5V | 12V | -5V | 5V | 12V | -12V | 5V | 15V | -15V | 5V | 12V | 24V |
| RATED CURRENT | 0~7A | 0~1A | 0~1A | 0~5A | 0~1A | 0~1A | 0~4A | 0~1A | 0~1A | 0~3A | 0~1A | 0~1A |
| RIPPLE&NOISE | 100m Vp-p |
100m Vp-p |
100m Vp-p |
100m Vp-p |
100m Vp-p |
100m Vp-p |
100m Vp-p |
120m Vp-p |
120m Vp-p |
50m Vp-p |
120m Vp-p |
120m Vp-p |
| EFFICIENCY | 66% | 69% | 71% | 72% | ||||||||
| ADJUSTABLE RANGE FOR DC VOLTAGE |
±10% | ±5% | ±5% | ±10% | ±5% | ±5% | ±10% | ±5% | ±5% | ±10% | ±5% | ±5% |
| LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±1% | ±1% |
| LOAD REGULATION | ±0.5% | ±4% | ±4% | ±1% | ±4% | ±4% | ±1% | ±4% | ±4% | ±1% | ±4% | ±4% |
| SETUP,RISE,HOLD UP TIME |
200ms,50ms,16ms/230VAC at full load | |||||||||||
| VOLTAGE RANGE |
90-132VAC/180-264VDC by switch 254-370VDC | |||||||||||
| FREQUENCY RANGE |
47-63HZ | |||||||||||
| IMPACT CURRENT | Cold start current 20A/115VAC 40A/230VAC | |||||||||||
| OVERLOAD PROTECTION |
105-150% cut offtheoutput, automatic recovery | |||||||||||
| OVER VOLTAGE PROTECTION | CH1:115-135% shut down O/P voltage ,re-power on to recover. | |||||||||||
| WORKING TEMP | -10~ +50°C | |||||||||||
| WITHSTAND VOLTAGE |
I/P-O/P:1.5KV I/P-FG:1.5KV O/P-FG:0.5KV 1minute | |||||||||||
| ISOLATION RESISTANCE |
I/P-O/P,I/P-FG,O/P-FG:500VDC/100M Ohms | |||||||||||
| DIMENSION | 159*98*38mm | |||||||||||
| WEIGHT | 34*32*24cm/30pcs/16.5kg | |||||||||||