Model Specification |
D-120A
|
D-120B
|
||
CH1
|
CH2
|
CH1
|
CH2
|
|
DC output voltage |
5V
|
12V
|
5V
|
24V
|
Output voltage error(Note:2) |
±2% |
±6%
|
±2%
|
±7%
|
Rated output current |
12A |
5A
|
6A
|
4A
|
Output current rage |
2-12A |
0.5-5A
|
2-10A
|
0.4-4A
|
Wave and noise(Note :3) |
60mVp-p
|
120mVp-p
|
60mVp-p
|
150mVp-p
|
Inlet stability(Note :4) |
±0.5%
|
±1%
|
±0.5%
|
±1%
|
Load stablity (Note :5) |
±0.5%
|
±5%
|
±0.5%
|
±6%
|
DC output power | 120W | 126W | ||
Efficiency | 78% | 80% | ||
Adjustable range for DC voltage | CH1;+10,-5% | CH1:+10,-5% | ||
AC input voltage range | 88-132VAC/176-264VAC 47-63Hz,248-370VDC | |||
Input current | 2.5A/115V 1.25A/230A | |||
AC INnrush current | Cold-start current 35A | |||
Leakage current | <3.5mA/240VAC | |||
Overload proctection | 105%-150%Type:Foldback:current limiting reset:auto recovery | |||
Over-voltage protection | CH1:5.75~6.75V | |||
High-temperature protection | ………… | |||
Temperature coefficient | ±0.03%/℃(0-50℃)ON+5V | |||
Setup rise hold up time | 200ms,50ms,20ms | |||
Vibration | 10-500Hz,2G 10min,/1cycle,Period for60min,Each axes | |||
Withstand voltage | Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC | |||
Isolation resistance | Input and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ | |||
Working temperature and humidity | -10℃~+60℃(Refer to output derating curve),20%~90%RH | |||
Store temperature and humidity | -20℃~+85℃。10%~95%RH | |||
Overall dimension | 199×110×50mm | |||
Weight | 0.85Kgs | |||
Safety standards | UL1950 TUVEN60950 | |||
EMC standards | CISPR22(EN55022)class B,IEC801-2,3,4,IEC555-2 Approved | |||
Note: 1.The testing condition for the paramenter above is :230VAC input,rated load,25℃70% RH.Humidity. 2.Error.include the setting error,line stability and load stability.(Note:5). 3.Wave test:adopting “A12″double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. 4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. 5.Load stability test:the load is from 0% to 100%. 6.Total output canbe maximum Current,total load can not exceed the maximum output power 7、C2、3、6 must be knocked down. |
D-120 Daul output switching power supply
D-120 Daul output switching power supply Low price and high reliability 105℃ output capacitor AC input power suitable for the world Hight efficiency and low operation temperature Soft-start current can reduce the AC input impact effecticly With Short-circuit and owwerload protection Compact size,light weight 100% full-load burning test Installed with EMI filter,minimum wave