| MODEL | Q-120B | Q-120C | Q-120D | |||||||||
| DC VOLTAGE | 5V | 12V | -5V | -12V | 5V | 15V | -5V | -15V | 5V | 12V | 24V | -12V |
| RATED CURRENT | 0~11A | 0~4A | 0~1A | 0~1A | 0~10A | 0~3.5A | 0~1A | 0~1A | 0-8A | 0~2A | 0~2A | 0~1A |
| RIPPLE&NOISE | 80m Vp-p |
120m Vp-p |
80m Vp-p |
120m Vp-p |
80m Vp-p |
150m Vp-p |
80m Vp-p |
150m Vp-p |
80m Vp-p |
120m Vp-p |
180m Vp-p |
120m Vp-p |
| EFFICIENCY | 77% | 76% | 80% | |||||||||
| LOAD STABILITY | ±0.5% | ±5% | ±5% | ±5% | ±0.5% | ±6% | ±5% | ±6% | ±5% | ±5% | ±5% | ±5% |
| LINE REGULATION | ±0.5% | ±1% | ±1% | ±1% | ±0.5% | ±1% | ±1% | ±1% | ±0.5% | ±1% | ±1% | ±1% |
| ADJUSTABLE RANGE FOR DC VOLTAGE |
±10% | ±5% | ±5% | ±5% | ±10% | ±5% | ±5% | ±5% | ±10% | ±5% | ±5% | ±5% |
| SETUP,RISE,HOLD UP TIME |
200ms,50ms,20ms/230VAC at full load | |||||||||||
| VOLTAGE RANGE |
90-132VAC/180-264VAC by switch 254-370VDC | |||||||||||
| FREQUENCY RANGE |
47-63HZ | |||||||||||
| IMPACT CURRENT | Cold start current 35A/230VAC | |||||||||||
| OVERLOAD PROTECTION |
105-150% cut off the output, automatic recovery | |||||||||||
| OVER VOLTAGE PROTECTION | CH1:115-135% shut down O/P voltage ,re-power on to recover. | |||||||||||
| WORKING TEMP | -10~ +50°C | |||||||||||
| WITHSTAND VOLTAGE |
I/P-O/P:1.5KV I/P-FG:1.5KV O/P-FG:0.5KV 1minute | |||||||||||
| ISOLATION RESISTANCE |
I/P-O/P,I/P-FG,O/P-FG:500VDC/100M Ohms | |||||||||||
| DIMENSION | 199*110*50mm | |||||||||||
| WEIGHT | 0.9kg | |||||||||||
| PACKING | 42*31.5*26cm/20pcs/16kg | |||||||||||