| Model | LPV-200-12 | LPV-200-24 | |
| output | DC voltage | 12V | 24V |
| Voltage tolerance | ±1% | ±1% | |
| Current range | 0~16.5A | 0~8.3A | |
| Ripple&noise | 150mvp-p | 200mvp-p | |
| input | Voltage range | 180~264VAC,255~373VDC | |
| Frequency | 47~63HZ | ||
| AC current | 2.5A/230VAC | ||
| Efficiency | 82% | 84% | |
| Inrush current | Cold start current 40A/230VAC | ||
| Leakage current | <2.5mA/240VAC | ||
| protection | Over load | Rated output power 105%~135%start over load protection | |
| Protection type:hiccup mode,auto-recovery after fault condition is removed | |||
| Over voltage | 15.6~17.8V | 30.6~33.2V | |
| Protection type:hiccup mode,auto-recovery after fault condition is removed | |||
| Over temperature | Shell temp≥85℃,start over temperature protection | ||
| Protection mode:cutoff output,auto-recovery after temperature become normal | |||
| environment | Working temp,humidity | -10℃~+60℃,20%~90%RH | |
| Storage temp.humidity | -20℃~+85℃,10%~95%RH non condensing | ||
| Withstand vibration | 10~500HZ,2G 10min/1cycle,period for 60minutes,each axes | ||
| safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |
| Isolated resistance | I/P-O/P、I/P-FG、O/P-FG:100M ohms/500VDC | ||
| Fits | Safety standard | Fit UL1012,IP67 protect level | |
| tandard | EMC standard | Fit EN55022,CLASSA | |
| Others | Dimension | 240*69*43mm (L*W*H) | |
| Weight/packing | 1.26kg/20pcs/26kg/0.033 m³/1.15CUFT | ||